silver wire electrode Search Results


90
Cygnus Technologies tungsten microelectrodes
Tungsten Microelectrodes, supplied by Cygnus Technologies, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/silver+wire+electrode/silver+wire+electrodes/pmc04593977-69-8-17
Average 90 stars, based on 1 article reviews
tungsten microelectrodes - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
A-M Systems bipolar silver wire electrode
Bipolar Silver Wire Electrode, supplied by A-M Systems, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/silver+wire+electrode/bipolar+silver+wire+electrode/pmc04346755-141-19-23
Average 90 stars, based on 1 article reviews
bipolar silver wire electrode - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
A-M Systems perfluoroalkoxy-alkane-insulated silver wire electrode (203 μ m uncoated diamter
Perfluoroalkoxy Alkane Insulated Silver Wire Electrode (203 μ M Uncoated Diamter, supplied by A-M Systems, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/silver+wire+electrode/perfluoroalkoxy+alkane+insulated+silver+wire+electrode/pmc04766044-188-6-15
Average 90 stars, based on 1 article reviews
perfluoroalkoxy-alkane-insulated silver wire electrode (203 μ m uncoated diamter - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
A-M Systems reference and ground electrodes teflon-coated silver wires
Reference And Ground Electrodes Teflon Coated Silver Wires, supplied by A-M Systems, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/silver+wire+electrode/teflon+coated+silver+wire+electrodes/pm37258700-271-2-7
Average 90 stars, based on 1 article reviews
reference and ground electrodes teflon-coated silver wires - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
A-M Systems silver wire electrodes
Overview of an insect-computer hybrid robot. (a) Live beetle with mounted backpack. (b) The wireless backpack (electrical stimulator) was customized using the TI CC2431 microcontroller with the tiny I/O header for connecting the <t>electrodes</t> and a microbattery. (c) The battery was wrapped with retro-reflective tape and mounted on the top of the backpack to supply power and serve as a marker for motion tracking. (d) Lateral view of the beetle with a close-up view of the direct flight muscles after dissecting the cuticle. The subalar muscle is located in the posterior part of the thorax, next to the basalar muscle. It runs from the hind leg coxa to an apodema that connects to the subalar sclerite. (e) Dorsal view of the beetle after removal of the elytra. Exposed view of the subalar sclerite showing connection to the wing base via a flexible membrane.
Silver Wire Electrodes, supplied by A-M Systems, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/silver+wire+electrode/silver+wire+electrodes/pmc09494732-39-1-21
Average 90 stars, based on 1 article reviews
silver wire electrodes - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
A-M Systems bipolar silver wire electrode no.7855
Overview of an insect-computer hybrid robot. (a) Live beetle with mounted backpack. (b) The wireless backpack (electrical stimulator) was customized using the TI CC2431 microcontroller with the tiny I/O header for connecting the <t>electrodes</t> and a microbattery. (c) The battery was wrapped with retro-reflective tape and mounted on the top of the backpack to supply power and serve as a marker for motion tracking. (d) Lateral view of the beetle with a close-up view of the direct flight muscles after dissecting the cuticle. The subalar muscle is located in the posterior part of the thorax, next to the basalar muscle. It runs from the hind leg coxa to an apodema that connects to the subalar sclerite. (e) Dorsal view of the beetle after removal of the elytra. Exposed view of the subalar sclerite showing connection to the wing base via a flexible membrane.
Bipolar Silver Wire Electrode No.7855, supplied by A-M Systems, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/silver+wire+electrode/bipolar+silver+wire+electrode+no++7855/pm17541215-49-14-19
Average 90 stars, based on 1 article reviews
bipolar silver wire electrode no.7855 - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Sigmund Cohn Corporation bipolar teflon insulated silver wire electrode medwire
Overview of an insect-computer hybrid robot. (a) Live beetle with mounted backpack. (b) The wireless backpack (electrical stimulator) was customized using the TI CC2431 microcontroller with the tiny I/O header for connecting the <t>electrodes</t> and a microbattery. (c) The battery was wrapped with retro-reflective tape and mounted on the top of the backpack to supply power and serve as a marker for motion tracking. (d) Lateral view of the beetle with a close-up view of the direct flight muscles after dissecting the cuticle. The subalar muscle is located in the posterior part of the thorax, next to the basalar muscle. It runs from the hind leg coxa to an apodema that connects to the subalar sclerite. (e) Dorsal view of the beetle after removal of the elytra. Exposed view of the subalar sclerite showing connection to the wing base via a flexible membrane.
Bipolar Teflon Insulated Silver Wire Electrode Medwire, supplied by Sigmund Cohn Corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/silver+wire+electrode/bipolar+teflon+insulated+silver+wire+electrode+medwire/10__1097_slash_psy__0b013e31816ff7dd-73-2-13
Average 90 stars, based on 1 article reviews
bipolar teflon insulated silver wire electrode medwire - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Leico Industries Inc teflon coated seven-stranded silver wire
Overview of an insect-computer hybrid robot. (a) Live beetle with mounted backpack. (b) The wireless backpack (electrical stimulator) was customized using the TI CC2431 microcontroller with the tiny I/O header for connecting the <t>electrodes</t> and a microbattery. (c) The battery was wrapped with retro-reflective tape and mounted on the top of the backpack to supply power and serve as a marker for motion tracking. (d) Lateral view of the beetle with a close-up view of the direct flight muscles after dissecting the cuticle. The subalar muscle is located in the posterior part of the thorax, next to the basalar muscle. It runs from the hind leg coxa to an apodema that connects to the subalar sclerite. (e) Dorsal view of the beetle after removal of the elytra. Exposed view of the subalar sclerite showing connection to the wing base via a flexible membrane.
Teflon Coated Seven Stranded Silver Wire, supplied by Leico Industries Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/silver+wire+electrode/teflon+coated+silver+wire+electrode/pmc04642941-62-5-14
Average 90 stars, based on 1 article reviews
teflon coated seven-stranded silver wire - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Intracel Corp loop-tipped silver wire ø
Overview of an insect-computer hybrid robot. (a) Live beetle with mounted backpack. (b) The wireless backpack (electrical stimulator) was customized using the TI CC2431 microcontroller with the tiny I/O header for connecting the <t>electrodes</t> and a microbattery. (c) The battery was wrapped with retro-reflective tape and mounted on the top of the backpack to supply power and serve as a marker for motion tracking. (d) Lateral view of the beetle with a close-up view of the direct flight muscles after dissecting the cuticle. The subalar muscle is located in the posterior part of the thorax, next to the basalar muscle. It runs from the hind leg coxa to an apodema that connects to the subalar sclerite. (e) Dorsal view of the beetle after removal of the elytra. Exposed view of the subalar sclerite showing connection to the wing base via a flexible membrane.
Loop Tipped Silver Wire ø, supplied by Intracel Corp, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/silver+wire+electrode/short+loop+tipped+silver+wire+electrode/pm19535396-74-4-9
Average 90 stars, based on 1 article reviews
loop-tipped silver wire ø - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
A-M Systems 140-μm-diameter teflon-coated silver wire 785500
Overview of an insect-computer hybrid robot. (a) Live beetle with mounted backpack. (b) The wireless backpack (electrical stimulator) was customized using the TI CC2431 microcontroller with the tiny I/O header for connecting the <t>electrodes</t> and a microbattery. (c) The battery was wrapped with retro-reflective tape and mounted on the top of the backpack to supply power and serve as a marker for motion tracking. (d) Lateral view of the beetle with a close-up view of the direct flight muscles after dissecting the cuticle. The subalar muscle is located in the posterior part of the thorax, next to the basalar muscle. It runs from the hind leg coxa to an apodema that connects to the subalar sclerite. (e) Dorsal view of the beetle after removal of the elytra. Exposed view of the subalar sclerite showing connection to the wing base via a flexible membrane.
140 μm Diameter Teflon Coated Silver Wire 785500, supplied by A-M Systems, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/silver+wire+electrode/twisted+teflon+coated+silver+wire+electrodes+786000/pmc02820366-676-10-12
Average 90 stars, based on 1 article reviews
140-μm-diameter teflon-coated silver wire 785500 - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Omnetics Connector Corporation bilateral silver wire eeg and ecg electrodes
Corticolimbic Kcna1 conditional knockout mice exhibit ictal cardiac dysfunction. ( A ) Quantification of the incidence of various cardiac abnormalities during seizures (ictal) and post-ictal periods. The bars represent the percentage of total seizures in which they occurred ( n = 52 seizures in 4 conditional knockout mice: 1 male, 3 females; 2–18 seizures per animal). Blocks = cardiac conduction blocks or sinus pauses; Brady = bradycardia; Tachy = tachycardia. ( B ) Representative <t>EEG-ECG</t> recording of a seizure with an ictal cardiac conduction block or sinus pause. The left panel displays the full-length EEG seizure and the corresponding <t>ECG</t> activity, with seizure onset and termination marked by the dotted lines. The right panel provides an expanded view of the area in the dashed box from the left panel, highlighting the conduction block or sinus pause, which is indicated by an arrow. ( C ) Representative EEG-ECG recording of a seizure with ictal bradycardia. The left panel displays the full-length EEG seizure and the corresponding ECG activity, with seizure onset and termination marked by the dotted lines. Movement artefacts (m) are indicated in the ECG trace. The right panel provides an expanded view of the area in the dashed box from the left panel, highlighting the bradycardia event, which is indicated by bars above the corresponding ECG segments with the rates labeled in beats per minute (bpm).
Bilateral Silver Wire Eeg And Ecg Electrodes, supplied by Omnetics Connector Corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/silver+wire+electrode/bilateral+silver+wire+eeg+and+ecg+electrodes/pmc11735082-54-30-39
Average 90 stars, based on 1 article reviews
bilateral silver wire eeg and ecg electrodes - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Omnetics Connector Corporation female silver wire electrodes .025"/.64mm nps-09-wd-18.0-c-gs
Corticolimbic Kcna1 conditional knockout mice exhibit ictal cardiac dysfunction. ( A ) Quantification of the incidence of various cardiac abnormalities during seizures (ictal) and post-ictal periods. The bars represent the percentage of total seizures in which they occurred ( n = 52 seizures in 4 conditional knockout mice: 1 male, 3 females; 2–18 seizures per animal). Blocks = cardiac conduction blocks or sinus pauses; Brady = bradycardia; Tachy = tachycardia. ( B ) Representative <t>EEG-ECG</t> recording of a seizure with an ictal cardiac conduction block or sinus pause. The left panel displays the full-length EEG seizure and the corresponding <t>ECG</t> activity, with seizure onset and termination marked by the dotted lines. The right panel provides an expanded view of the area in the dashed box from the left panel, highlighting the conduction block or sinus pause, which is indicated by an arrow. ( C ) Representative EEG-ECG recording of a seizure with ictal bradycardia. The left panel displays the full-length EEG seizure and the corresponding ECG activity, with seizure onset and termination marked by the dotted lines. Movement artefacts (m) are indicated in the ECG trace. The right panel provides an expanded view of the area in the dashed box from the left panel, highlighting the bradycardia event, which is indicated by bars above the corresponding ECG segments with the rates labeled in beats per minute (bpm).
Female Silver Wire Electrodes .025"/.64mm Nps 09 Wd 18.0 C Gs, supplied by Omnetics Connector Corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/silver+wire+electrode/male+silver+wire+electrodes++025+++64mm/pmc09753929-26-8-6
Average 90 stars, based on 1 article reviews
female silver wire electrodes .025"/.64mm nps-09-wd-18.0-c-gs - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

Image Search Results


Overview of an insect-computer hybrid robot. (a) Live beetle with mounted backpack. (b) The wireless backpack (electrical stimulator) was customized using the TI CC2431 microcontroller with the tiny I/O header for connecting the electrodes and a microbattery. (c) The battery was wrapped with retro-reflective tape and mounted on the top of the backpack to supply power and serve as a marker for motion tracking. (d) Lateral view of the beetle with a close-up view of the direct flight muscles after dissecting the cuticle. The subalar muscle is located in the posterior part of the thorax, next to the basalar muscle. It runs from the hind leg coxa to an apodema that connects to the subalar sclerite. (e) Dorsal view of the beetle after removal of the elytra. Exposed view of the subalar sclerite showing connection to the wing base via a flexible membrane.

Journal: Cyborg and Bionic Systems

Article Title: A Cyborg Insect Reveals a Function of a Muscle in Free Flight

doi: 10.34133/2022/9780504

Figure Lengend Snippet: Overview of an insect-computer hybrid robot. (a) Live beetle with mounted backpack. (b) The wireless backpack (electrical stimulator) was customized using the TI CC2431 microcontroller with the tiny I/O header for connecting the electrodes and a microbattery. (c) The battery was wrapped with retro-reflective tape and mounted on the top of the backpack to supply power and serve as a marker for motion tracking. (d) Lateral view of the beetle with a close-up view of the direct flight muscles after dissecting the cuticle. The subalar muscle is located in the posterior part of the thorax, next to the basalar muscle. It runs from the hind leg coxa to an apodema that connects to the subalar sclerite. (e) Dorsal view of the beetle after removal of the elytra. Exposed view of the subalar sclerite showing connection to the wing base via a flexible membrane.

Article Snippet: Two silver wire electrodes (diameter of the bare wire, 127 μ m, and diameter of the coated wire, 178 μ m; A-M Systems) were implanted into the subalar muscle at a depth of 3 mm through a small opening on the cuticle.

Techniques: Battery, Marker, Muscles, Membrane

Electromyography of the beetle during visual stimulation. (a) The beetle was mounted in front of two monitors (form an angle of 120 degrees) for visual stimulation. Vertical black/white stripes moved at around 10 Hz to emulate forward/backward visual stream. A pair of silver electrodes were implanted into the subalar muscle for recording EMG signal. (b) The subalar muscle fired continuously during beetle flight. (c) It was most active during fictive decelerating flight, with a firing rate of 25.3 Hz, which decreased to 21.6 ( p < 0.05, paired sample t -test) during the period of no stimulation.

Journal: Cyborg and Bionic Systems

Article Title: A Cyborg Insect Reveals a Function of a Muscle in Free Flight

doi: 10.34133/2022/9780504

Figure Lengend Snippet: Electromyography of the beetle during visual stimulation. (a) The beetle was mounted in front of two monitors (form an angle of 120 degrees) for visual stimulation. Vertical black/white stripes moved at around 10 Hz to emulate forward/backward visual stream. A pair of silver electrodes were implanted into the subalar muscle for recording EMG signal. (b) The subalar muscle fired continuously during beetle flight. (c) It was most active during fictive decelerating flight, with a firing rate of 25.3 Hz, which decreased to 21.6 ( p < 0.05, paired sample t -test) during the period of no stimulation.

Article Snippet: Two silver wire electrodes (diameter of the bare wire, 127 μ m, and diameter of the coated wire, 178 μ m; A-M Systems) were implanted into the subalar muscle at a depth of 3 mm through a small opening on the cuticle.

Techniques:

Corticolimbic Kcna1 conditional knockout mice exhibit ictal cardiac dysfunction. ( A ) Quantification of the incidence of various cardiac abnormalities during seizures (ictal) and post-ictal periods. The bars represent the percentage of total seizures in which they occurred ( n = 52 seizures in 4 conditional knockout mice: 1 male, 3 females; 2–18 seizures per animal). Blocks = cardiac conduction blocks or sinus pauses; Brady = bradycardia; Tachy = tachycardia. ( B ) Representative EEG-ECG recording of a seizure with an ictal cardiac conduction block or sinus pause. The left panel displays the full-length EEG seizure and the corresponding ECG activity, with seizure onset and termination marked by the dotted lines. The right panel provides an expanded view of the area in the dashed box from the left panel, highlighting the conduction block or sinus pause, which is indicated by an arrow. ( C ) Representative EEG-ECG recording of a seizure with ictal bradycardia. The left panel displays the full-length EEG seizure and the corresponding ECG activity, with seizure onset and termination marked by the dotted lines. Movement artefacts (m) are indicated in the ECG trace. The right panel provides an expanded view of the area in the dashed box from the left panel, highlighting the bradycardia event, which is indicated by bars above the corresponding ECG segments with the rates labeled in beats per minute (bpm).

Journal: Brain Communications

Article Title: Seizures and premature death in mice with targeted Kv1.1 deficiency in corticolimbic circuits

doi: 10.1093/braincomms/fcae444

Figure Lengend Snippet: Corticolimbic Kcna1 conditional knockout mice exhibit ictal cardiac dysfunction. ( A ) Quantification of the incidence of various cardiac abnormalities during seizures (ictal) and post-ictal periods. The bars represent the percentage of total seizures in which they occurred ( n = 52 seizures in 4 conditional knockout mice: 1 male, 3 females; 2–18 seizures per animal). Blocks = cardiac conduction blocks or sinus pauses; Brady = bradycardia; Tachy = tachycardia. ( B ) Representative EEG-ECG recording of a seizure with an ictal cardiac conduction block or sinus pause. The left panel displays the full-length EEG seizure and the corresponding ECG activity, with seizure onset and termination marked by the dotted lines. The right panel provides an expanded view of the area in the dashed box from the left panel, highlighting the conduction block or sinus pause, which is indicated by an arrow. ( C ) Representative EEG-ECG recording of a seizure with ictal bradycardia. The left panel displays the full-length EEG seizure and the corresponding ECG activity, with seizure onset and termination marked by the dotted lines. Movement artefacts (m) are indicated in the ECG trace. The right panel provides an expanded view of the area in the dashed box from the left panel, highlighting the bradycardia event, which is indicated by bars above the corresponding ECG segments with the rates labeled in beats per minute (bpm).

Article Snippet: To record in vivo brain and heart activity, mice (4–6 weeks old) of both sexes were anaesthetized using an anaesthetic cocktail and surgically implanted with bilateral silver wire EEG and ECG electrodes (0.005-inch diameter) attached to a microminiature connector (Omnetics Connector Corporation, Minneapolis, MN, USA) for recording in a tethered configuration, as described previously., Briefly, EEG wires were inserted into the subdural space through cranial burr holes overlying the parietotemporal cortex for the recording electrodes and above the frontal cortex for the ground and reference electrodes.

Techniques: Knock-Out, Blocking Assay, Activity Assay, Labeling

Corticolimbic Kcna1 conditional knockout mice exhibit ictal respiratory dysfunction. ( A ) Quantification of the incidence of various respiratory abnormalities during seizures. The bars represent the percentage of total seizures in which they occurred ( n = 10 seizures in 3 conditional knockout mice: 1 male, 2 females; 2–6 seizures per animal). Tachy = tachypnea; Atx = ataxic-like breathing patterns; Hypo = hypopnea; Brady = bradypnea; Gasp = gasping. ( B ) Representative plethysmography (pleth) trace of ictal tachypnea with corresponding EEG seizure activity. The breathing rates before (left) and during (right) the tachypnea event are indicated by bars above the corresponding pleth segments with the rates labeled in breaths per minute (brpm). ( C ) Representative pleth trace showing ictal ataxic-like breathing patterns (indicated by the labeled bar) with corresponding EEG seizure activity. ( D ) Representative EEG-ECG-pleth recording of a seizure that initiates ictal tachypnea before ictal tachycardia. The dotted line marks onset of the seizure. Heart rate (bpm, beats per minute) and breathing rate (brpm, breaths per minute) are labeled above the corresponding ECG and pleth segments, respectively. As outlined in the Materials and methods, tachycardia and tachypnea were defined as rate increases of at least 20% relative to the 20-s pre-ictal period immediately prior to seizure onset. Movement artefacts (m) are indicated in the ECG trace.

Journal: Brain Communications

Article Title: Seizures and premature death in mice with targeted Kv1.1 deficiency in corticolimbic circuits

doi: 10.1093/braincomms/fcae444

Figure Lengend Snippet: Corticolimbic Kcna1 conditional knockout mice exhibit ictal respiratory dysfunction. ( A ) Quantification of the incidence of various respiratory abnormalities during seizures. The bars represent the percentage of total seizures in which they occurred ( n = 10 seizures in 3 conditional knockout mice: 1 male, 2 females; 2–6 seizures per animal). Tachy = tachypnea; Atx = ataxic-like breathing patterns; Hypo = hypopnea; Brady = bradypnea; Gasp = gasping. ( B ) Representative plethysmography (pleth) trace of ictal tachypnea with corresponding EEG seizure activity. The breathing rates before (left) and during (right) the tachypnea event are indicated by bars above the corresponding pleth segments with the rates labeled in breaths per minute (brpm). ( C ) Representative pleth trace showing ictal ataxic-like breathing patterns (indicated by the labeled bar) with corresponding EEG seizure activity. ( D ) Representative EEG-ECG-pleth recording of a seizure that initiates ictal tachypnea before ictal tachycardia. The dotted line marks onset of the seizure. Heart rate (bpm, beats per minute) and breathing rate (brpm, breaths per minute) are labeled above the corresponding ECG and pleth segments, respectively. As outlined in the Materials and methods, tachycardia and tachypnea were defined as rate increases of at least 20% relative to the 20-s pre-ictal period immediately prior to seizure onset. Movement artefacts (m) are indicated in the ECG trace.

Article Snippet: To record in vivo brain and heart activity, mice (4–6 weeks old) of both sexes were anaesthetized using an anaesthetic cocktail and surgically implanted with bilateral silver wire EEG and ECG electrodes (0.005-inch diameter) attached to a microminiature connector (Omnetics Connector Corporation, Minneapolis, MN, USA) for recording in a tethered configuration, as described previously., Briefly, EEG wires were inserted into the subdural space through cranial burr holes overlying the parietotemporal cortex for the recording electrodes and above the frontal cortex for the ground and reference electrodes.

Techniques: Knock-Out, Activity Assay, Labeling

A SUDEP event in a corticolimbic Kcna1 conditional knockout mouse. ( A ) Recording of simultaneous EEG-ECG-pleth activity during a spontaneous seizure in a 30-day old female conditional knockout mouse. Top, Trace indicates the neural EEG signal; middle , trace represents the cardiac ECG signal; bottom , trace shows the respiratory plethysmography (Pleth) signal. Onset and termination of the seizure are indicated by the dotted lines. ( B ) Respiratory (brpm) and heart rates per minute (bpm) corresponding to the recording in A . Each dot in the plot represents a 10-s mean value. Time 0 represents seizure onset, and the pre-ictal segment shows the 60-s immediately preceding seizure onset. Some movement artefacts were present in the pleth and ECG signals; therefore, scoring of breaths and heartbeats was done manually as needed. The respiratory rate data points at 40-s and 50-s were omitted, resulting in a discontinuous line, because convulsive seizure activity hindered accurate rate calculations. ( C ) Expanded 10-s traces of EEG, ECG and pleth at the times indicated by the solid lines numbered 1–5 in A . The numbers mark the following events: 1, pre-ictal phase; 2, tachypnea with slightly increased heart rate shortly after seizure onset; 3, ataxic-like breathing patterns and mild bradycardia shortly before seizure termination; 4, onset of post-ictal generalized EEG suppression with terminal apnoea and severe bradycardia; 5, extreme post-ictal bradycardia. The high frequency activity in the ECG during portions of the seizure reflects skeletal muscle activity.

Journal: Brain Communications

Article Title: Seizures and premature death in mice with targeted Kv1.1 deficiency in corticolimbic circuits

doi: 10.1093/braincomms/fcae444

Figure Lengend Snippet: A SUDEP event in a corticolimbic Kcna1 conditional knockout mouse. ( A ) Recording of simultaneous EEG-ECG-pleth activity during a spontaneous seizure in a 30-day old female conditional knockout mouse. Top, Trace indicates the neural EEG signal; middle , trace represents the cardiac ECG signal; bottom , trace shows the respiratory plethysmography (Pleth) signal. Onset and termination of the seizure are indicated by the dotted lines. ( B ) Respiratory (brpm) and heart rates per minute (bpm) corresponding to the recording in A . Each dot in the plot represents a 10-s mean value. Time 0 represents seizure onset, and the pre-ictal segment shows the 60-s immediately preceding seizure onset. Some movement artefacts were present in the pleth and ECG signals; therefore, scoring of breaths and heartbeats was done manually as needed. The respiratory rate data points at 40-s and 50-s were omitted, resulting in a discontinuous line, because convulsive seizure activity hindered accurate rate calculations. ( C ) Expanded 10-s traces of EEG, ECG and pleth at the times indicated by the solid lines numbered 1–5 in A . The numbers mark the following events: 1, pre-ictal phase; 2, tachypnea with slightly increased heart rate shortly after seizure onset; 3, ataxic-like breathing patterns and mild bradycardia shortly before seizure termination; 4, onset of post-ictal generalized EEG suppression with terminal apnoea and severe bradycardia; 5, extreme post-ictal bradycardia. The high frequency activity in the ECG during portions of the seizure reflects skeletal muscle activity.

Article Snippet: To record in vivo brain and heart activity, mice (4–6 weeks old) of both sexes were anaesthetized using an anaesthetic cocktail and surgically implanted with bilateral silver wire EEG and ECG electrodes (0.005-inch diameter) attached to a microminiature connector (Omnetics Connector Corporation, Minneapolis, MN, USA) for recording in a tethered configuration, as described previously., Briefly, EEG wires were inserted into the subdural space through cranial burr holes overlying the parietotemporal cortex for the recording electrodes and above the frontal cortex for the ground and reference electrodes.

Techniques: Knock-Out, Activity Assay